4 products
Sort by
Sort by
Save 14%
#BTU_9000 BTU SEER2 19 Up to 400 Sp.Ft. #BTU_18000 BTU SEER2 19 Up to 1000 Sp.Ft.

DELLA Versa Series Mini Split AC 16.4ft Installation Kits

Sale priceFrom $629.96 Regular price$729.96
Save 18%
DELLA Motto Series Mini Split AC R32 Refrigerant #BTU_9000 BTU SEER2 17 Up to 400 Sp.Ft.

DELLA Motto Series Mini Split AC R32 Refrigerant

Sale priceFrom $549.96 Regular price$669.96
Save 13%
DELLA Umbra Series Mini Split AC R32 Refrigerant #BTU_12000 BTU SEER2 20 Up to 550 Sp.Ft.

DELLA Umbra Series Mini Split AC R32 Refrigerant

Sale priceFrom $649.96 Regular price$749.96
Save 11%
DELLA Optima Series Mini Split AC R410A Refrigerant #BTU_9000 BTU SEER2 23 Up to 400 Sp.Ft.

DELLA Optima Series Mini Split AC R410A Refrigerant

Sale priceFrom $849.96 Regular price$949.96

FAQs

1. How many sq ft will a 9,000 BTU mini split cool?

A 9,000 BTU mini split can typically cool a space of about 350 to 400 square feet. This range is based on the general rule that each BTU cools roughly 0.13 to 0.15 square feet. So, for most average rooms, a 9,000 BTU unit should work well within that size.

2. Is 9,000 BTU air conditioner too much for a bedroom?

A 9,000 BTU air conditioner is generally not too much for a bedroom. In fact, it's usually a good fit for bedrooms ranging from 150 to 400 square feet. The size of the room, insulation, and climate will affect the exact fit, but for most standard bedrooms, a 9,000 BTU unit should provide efficient cooling without being excessive.

If your bedroom is smaller, say around 150-250 square feet, a smaller unit (e.g., 6,000-8,000 BTU) might be more efficient, but a 9,000 BTU air conditioner unit will still work without problems. It might cool the room faster, but it won't harm the system—just make sure the temperature is set, so the air conditioner cycles properly.

3. What happens if you oversize a mini split?

If you oversize a mini split (i.e., choose a unit with too high a BTU rating for the space), several issues can arise:

Short Cycling: The air conditioner cools the room too quickly, causing it to turn on and off frequently. This reduces the system’s efficiency and lifespan, as it doesn’t run long enough to properly dehumidify the air.

Inadequate Dehumidification: Mini splits not only cool the air but also remove humidity. If the unit shuts off too quickly (due to being oversized), it won’t have enough time to effectively dehumidify the room, leaving the space feeling damp or muggy.

Higher Energy Costs: Although a larger unit may seem like it will cool faster, the frequent on/off cycling uses more energy and may lead to higher utility bills in the long run.

Inconsistent Temperature: With an oversized unit, you may notice temperature fluctuations, as the system may cool the room unevenly or not maintain a consistent temperature.

4. How many watts does a 9K BTU mini split use?

A 9K BTU mini split typically uses around 800 to 1,000 watts for cooling, depending on the brand and efficiency. For example, the Della TP 9,000 BTU mini split uses 710 watts for cooling and has a SEER2 rating of 19, making it highly energy-efficient compared to many other models.

5. How loud is a 9,000 BTU mini split?

A 9,000 BTU mini split typically operates with an indoor noise level ranging from 25 to 45 decibels (dBA), depending on the brand and model. For example, the Della TP 9,000 BTU mini split has an indoor noise level of 27 to 42 dBA and an outdoor unit noise level of 50 dBA, making it quiet enough for most home environments, including bedrooms and living spaces.

6. What are the electrical requirements for a 9,000 BTU mini split air conditioner?

A 9,000 BTU mini split air conditioner typically operates with an indoor noise level ranging from 25 to 45 decibels (dBA). For example, the Della TP 9,000 BTU mini split has an indoor noise level of 27 to 42 dBA and an outdoor unit noise level of 50 dBA, making it quiet enough for most home environments, including bedrooms and living spaces.

7. Is a 9,000 BTU mini split suitable for both heating and cooling?

Yes, a 9,000 BTU mini split is suitable for both heating and cooling. Many modern mini split systems, including the Della TP 9,000 BTU mini split, function as heat pumps, providing efficient cooling in summer and heating in winter.

For example, the Della TP 9,000 BTU mini split offers a rated cooling capacity of 9,000 BTU/h and a rated heating capacity of 9,500 BTU/h, making it an excellent choice for year-round comfort in spaces up to 400 square feet. This dual functionality is both energy-efficient and cost-effective.

8. Which Della's 9,000 BTU mini split is better?

The Opitma (TP) series is better overall due to its superior energy efficiency and better performance, and it balances performance and efficiency.

Comparison

  • Energy Efficiency: The Opitma (TP) series consumes less power (710W for cooling vs. 840W in TL), making it more energy-efficient.
  • Heating Performance: The Versa (TL) series has slightly better heating capacity (10,000 BTU vs. 9,500 BTU in TP), making it better for colder climates.
  • Noise Levels: The Versa (TL) series is quieter indoors (26-41 dBA vs. 27-42 dBA in TP), but the difference is minimal.
  • Size and Weight: The Versa (TL) series is more compact and lighter, making installation easier.

9. Is the 9K BTU mini split quiet enough for use in bedrooms or offices?

Yes, a 9,000 BTU mini split is quiet enough for use in bedrooms or offices. For example, the Della TP 9K BTU mini split operates at an indoor noise level of 27-42 dBA, which is similar to the sound of a quiet library or soft whisper. On average, most 9,000 BTU mini splits on the market operate between 28-45 dBA. This ensures the 9,000 BTU air conditioner won’t disturb sleep or concentration, making it an excellent choice for bedrooms or offices.

10. What maintenance is the 9,000 BTU mini split air conditioner required to keep it running efficiently?

To keep a 9,000 BTU mini split air conditioner running efficiently, regular maintenance is essential. Based on the reference materials provided, here are the key steps for routine maintenance:

Clean the Air Filter:

  • Lift the air filter by its tabs.
  • Wash it with soapy water (<104°F/40°C).
  • Air-dry the filter before reinstalling.
  • Clean the air filter every 3 months or more frequently if the environment is dusty or has poor air quality.

Clean the Indoor Unit:

  • Use a soft, dry cloth or a damp cloth with neutral detergent.
  • Avoid flushing the air conditioner with water.
  • Utilize the self-clean function every 3 months to maintain the indoor unit.

Inspect and Clean the Outdoor Unit:

  • Regularly check and remove any debris from the outdoor unit to ensure proper airflow.
  • Keep obstacles clear from the vents.

Check Refrigerant Levels:

  • Have an HVAC technician inspect the refrigerant level every 3–4 years to ensure optimal performance.

And seasonal or idle maintenance is needed as well:

Before Long-Term Storage:

  • Remove the batteries from the remote control.
  • Disconnect the power supply.
  • Clean the air filter and unit before storage.

After Long-Term Storage:

  • Clean the unit and air filter again.
  • Ensure the air inlets and outlets are clear of obstacles.
  • Verify the drain pipe is unobstructed.
  • Reinstall batteries in the remote control and reconnect the power.